AST RESEARCH TECHNICAL BULLETIN TB-0084 5-3-85
|
||
|
||
MGO 123/PREVU AND MAX 12E
|
||
|
||
Our customer base has reported that the Princeton Graphic MAX 12E
|
||
monitor does not function properly with the AST MonoGraphPlus or
|
||
Preview!
|
||
|
||
The symptom reported is that when high intensity is selected, the
|
||
monitor displays reverse video with no characters legible. This
|
||
symptom was reported using the display test in IBM diagnostics or
|
||
when using Turbo Pascal.
|
||
|
||
According to Princeton Graphic, Technical Support, the
|
||
incompatibility exists with AST as well as other manufacturers.
|
||
The short-term solution, according to Princeton Graphic, is to
|
||
remove D201. D201 is located on the main board next to the input
|
||
signal connector in the MAX 12E. Princeton Graphic did not
|
||
indicate what their long-term solution is but serial number
|
||
ky23501 through kw15861 will not have D201 installed.
|
||
|
||
AST recommends that Princeton Graphic be contacted for
|
||
confirmation and instructions of modification. |