AST RESEARCH, INC. TECHNICAL BULLETIN #0716 10-28-91
|
|
|
|
=============================================================================
|
|
|
|
|
|
AST PREMIUM II 386SX-20 AND TRAK ENGINEERING SOFTWARE
|
|
|
|
|
|
PROBLEM: The TRAK Engineering application software "Fuel Management
|
|
System" will not communicate with TRAK's custom control box
|
|
through the Premium II 386SX-20 Com port.
|
|
|
|
AFFECTED
|
|
SYSTEMS: AST Premium II 386SX-20 with the following system board part
|
|
number:
|
|
|
|
202373-003 Revision X4 and below
|
|
|
|
CAUSE: Incompatibility between TRAK Engineering software and control
|
|
box and AST's Com port on the Premium II 386SX-20 system.
|
|
|
|
SOLUTION: This problem has been resolved. Customers experiencing this
|
|
problem should contact AST and have their system board
|
|
upgraded to revision X5 or above.
|