AST RESEARCH, INC. TECHNICAL BULLETIN #0729 01-03-92
=============================================================================
AST PREMIUM II 386SX-20 AND DEC PCSA SOFTWARE
PROBLEM: System will not remote boot with DEC's PCSA revision 4.0E
software. The system will hang during the execution of the
CONFIG.SYS file.
AFFECTED
SYSTEM: AST Premium II 386SX-20 system.
CAUSE: Incompatibility between DEC's PCSA revision 4.0E software and
AST's Premium II 386SX-20 system.
SOLUTION: Customers experiencing this problem should contact DEC for a
software upgrade, PCSA revision 4.1 will resolve this problem.