AST RESEARCH, INC. TECHNICAL BULLETIN #0801 01-06-93
|
|
|
|
=============================================================================
|
|
|
|
|
|
BRAVO 486/33 AND PIXEL WORKS RA-1280
|
|
|
|
|
|
PROBLEM: When using the AST Bravo II 486/33 with the Pixel Works RA-
|
|
1280 graphics board installed, the diagnostic software bundled
|
|
with the RA-1280 may hang when running board tests, requiring
|
|
a cold boot to restart the system.
|
|
|
|
CAUSE: The RA-1280 is a bus-mastering card that is not compatible
|
|
with the Premium II, Premium CLEM, and Bravo II 486 series of
|
|
computers.
|
|
|
|
AFFECTED
|
|
SYSTEMS: AST Premium II systems.
|
|
AST Premium CLEM systems.
|
|
AST Bravo II 486 systems.
|
|
|
|
SOLUTION: AST Sustaining Engineering has determined that this problem
|
|
will not be fixed. AST suggests using an alternate graphics
|
|
adapter.
|
|
|