The Meridian Norstar Range Advanced Digital Phone Systems
|
|
|
|
from: Psyclone/mED
|
|
|
|
Meridian Norstar is a range of digital phone systems designed to operate in
|
|
any required configuration reaquired, as a keysystem (with a central
|
|
operator) , or working behind a large phone system. It features 128 line-
|
|
extension ports , access to multiple system features , loop disconnectand
|
|
multi-frequency dialling , hi-speed+hi-quality connections.... This type of
|
|
meridian system is a pbx not a mail system, so it is not like the ones many
|
|
of you are used to. It does not have mail boxes , just extensions. This is
|
|
the type of system that would be used in a office block or hotel, (this is
|
|
the system used in my school), basically it is a real- time interface.
|
|
There are are two types of Meridian Norstar, the difference between the two
|
|
systems is simply that the Norstar Compact is for smaller organizations and
|
|
the Norstar Modular is for larger ones. This varietymakes Norstar a popular
|
|
private network system. When i refer to "users" in this file i mean the
|
|
authorized usersas almost all of the system features in this file are only
|
|
valid for the local users (like system operators, secretaries, or
|
|
receptionists) and so may not betoo interesting to most of you.
|
|
|
|
The System features are : (in alpha order)
|
|
|
|
|
|
Access signalling : A user can dial access and activate remote equipment
|
|
and work within a private network.
|
|
|
|
Accidental dissconnect protection : Calls that are accidentally cut off are
|
|
automatically reconnected within one second.
|
|
|
|
Analogue terminal adapter : For connection of two wire devices such as
|
|
answering machines, fax machines, modems and external extensions.
|
|
|
|
Answer groups :On modular systems a single key can be used to answer up to
|
|
four extensions.
|
|
|
|
Auto-dial keys (int. and ext.) : One button provides access to features or
|
|
to frequently dialled numbers inside or outside the company.
|
|
|
|
Auto-line select : The system selects a free line for outgoing calls
|
|
automatically.
|
|
|
|
Automatic night service : The modular automatically switches to night
|
|
service at pre-programmed times. On Compact systems this is performed
|
|
manually.
|
|
|
|
Automatic fone relocation : Any fone can be moved from jack to jack ,
|
|
retaining its number and features.
|
|
|
|
Auxiliary ringer interface : For the connection of loud bells , hooters or
|
|
night service bells.
|
|
|
|
Backgroud music : Audio equipment can provide music via the fones
|
|
loudspeakers.
|
|
|
|
Busy lamp field : A user can make instant checks on extension status.
|
|
|
|
Call barring : Outgoing calls can be barred.
|
|
|
|
Call barring override : Allows bars to be lifted for specific destinations
|
|
or users.
|
|
|
|
Call duration timer : The duration of any call can be clocked via display.
|
|
|
|
Call forward : Forward calls to alternative extensions - all calls , busy
|
|
or no reply.
|
|
|
|
Call forward override : Allowes person taking the forwarded calls to bypass
|
|
call forward and contact the forwarding ext.
|
|
|
|
Call id / call status display : Internal calls activate the display to show
|
|
who is calling or the status of the call. external calls are identified by
|
|
the incoming line no.
|
|
|
|
Call logging interface : This add-on unit enables printers or call
|
|
management equipment to be connected to Norstar systems.
|
|
|
|
Call park : Holds a call in the system until it is picked up by a differant
|
|
extension.
|
|
|
|
Call pick-up : Group - A member of a group can answer another's call from
|
|
their own fone. Trunk answer - Exchange calls can be picked up from any
|
|
fone when a service mode is activated - ie night service.
|
|
|
|
Call queuing : On modular systems incoming trunk calls are presented to the
|
|
central answering point in the order in which they are were reiceived.
|
|
|
|
Camp on busy : This enables external calls on modular to e put through to
|
|
engaged extensions. The extension user is given a warning tone. The call is
|
|
is connected when the extension becomes free.
|
|
|
|
Centralised answering : Using a CAAP module, you can have operator working
|
|
on modular systems.
|
|
|
|
Confrencing : Three internal parties (or two) and one external party can
|
|
can be connected in three way conversation.
|
|
|
|
Delay ringer transfer : Transfers a call to another extension if not
|
|
answered.
|
|
|
|
Dial 0 extension : Provides single button acess to a specific fone (usually
|
|
operator).
|
|
|
|
Dialpad feedback : Each key press is accompanied by a tone and all keyed
|
|
numbers are displayed in screen.
|
|
|
|
Directable call pick-up : On modular systems calls can be picked up from
|
|
any other extension by keying in a feature code and the extension number.
|
|
|
|
Direct station select : Internal calls can be made via a single reprgrmmd
|
|
key. The busy lamp field or CAP module can be interogated to enhance the
|
|
operation.
|
|
|
|
Emergency telefones : If mains power fails, at least 25% or the lines ona
|
|
Norstar system can fall back on to BS6317 phones. If this occurs, calls can
|
|
be made and received but not switched.
|
|
|
|
Extension lock : This allows a user to prevent others from programming
|
|
their fone.
|
|
|
|
Extension to Extension Calling Over Private Networks : Calls can be made
|
|
direct between extensions at different sites via private networks.
|
|
|
|
7-digit extension numbering : On Modular systems on private networks
|
|
extensions can be numbered with up to 7 digits.
|
|
|
|
Group listening : The handset and speaker can be be connected at the same
|
|
time so the person can monitor a conversation or message without the
|
|
microfone picking up any background sounds.
|
|
|
|
Host delay : Allows time for the host system of a piggy-backed Norstar
|
|
system to access outside lines while calls are held.
|
|
|
|
Intrusion tone : Warns users that an internal call is about to interrrupt
|
|
an existing one.
|
|
|
|
Key enquiry : This allows the user to check the function, memories, and
|
|
feature keys on each of the lines.
|
|
|
|
Line pools : Exchange lines on private circuits can be grouped for outgoing
|
|
access and the users can be given access to specified groups only. (Up to 3
|
|
pools on Compact systems and 15 on Modular systems).
|
|
|
|
Liquid crystal displays : These are used on each phone to give phone and
|
|
call details in real time and to prompt users thro the call handling
|
|
features.
|
|
|
|
Operator controlled phone system (pbx) pause/programmed release/timed break
|
|
or earth recall/runstop : A group of features which allow Norstar systemsto
|
|
work behind a phone system which requires signals other than
|
|
multi-frequency tones.
|
|
|
|
Paging : *Internal - An integral paging system operates thro the fones
|
|
speakers and can page up to 3 zones on Compact systems and up to 6 on
|
|
Modular systems. *External - An external public address system can be
|
|
connected.
|
|
|
|
Prime line : A phone can be programmed to automatically select a certain
|
|
type of line whenever the handset is lifted.
|
|
|
|
Priority call : This allows a phone to interrupt another busy phone. The
|
|
interrupted party can only block the intruder within 8 seconds.
|
|
|
|
Private lines : An outside line can be exclusively allocated to a phone.
|
|
The only other line that can access this line is the Prime extension which
|
|
is used to receive all unanswered calls.
|
|
|
|
Public phone network breakout : On Norstar systems on private networks,
|
|
calls can be directed to breakout onto the public phone network via remote
|
|
phone systems.
|
|
|
|
Restriction override password : Allows a user to override all call
|
|
restrictions on any fone via a 4-digit code.
|
|
|
|
System memory protection : If the mains power fails, the system memory can
|
|
be retained for 3 days.
|
|
|
|
Tandem access : On private networks, Modular systems can switch between
|
|
sites.
|
|
|
|
Tone on conference : A warning tone is played when another user joins a
|
|
conference.
|
|
|
|
Volume Control : This allows separate control over the volume of the
|
|
headset, handset, hands-free, ringing, background, and paging.
|
|
|
|
|
|
|
|
Equipment Description:-
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Central Control Unit (CCU)
|
|
|
|
Each system comprises of a wall mounted CCU and a choice of four fones. All
|
|
features and system defaults are stored in software cartridges which slot
|
|
into the CCU. The system is set up on installation according to your
|
|
requirements, but you can alter the set-up yourself using an M7324 or M7310
|
|
phone as your programming tool on Modular systems, and an M7208, M7310 or
|
|
M7324 phone on Compact systems. A customised box connection, sited by the
|
|
CCU, provides simple connection of extensions to the system. It also
|
|
provides connections for various extras and interfaces.
|
|
|
|
|
|
Telephones:-
|
|
^^^^^^^^^^
|
|
|
|
M7324 - This is the fone used by the key personnel (admins). This fonehas
|
|
an optional CAP module which makes this fone the focal point of an
|
|
operator-based system.
|
|
M7310 - The phone for high volume users.
|
|
M7208 - Standard.
|
|
M7100 - Low use phone,which would sit on a desk at the end of an extesion.
|
|
|
|
All these phones are details in a chart at the end of this document.
|
|
|
|
All the fones have an LCD providing prompts to guide users through each
|
|
system function.
|
|
|
|
-Centralised Answering Position [CAP] module.
|
|
When this is added to the M7324 is becomes an operator's position, with
|
|
48 additional programmable keys. Modular systems can support 5 M7324's
|
|
with 2 CAP modules each.
|
|
|
|
|
|
Telephone options:-
|
|
^^^^^^^^^^^^^^^^^
|
|
M7100 M7208 M7310 M7324
|
|
|
|
Programmable Line Feature Keys 1 8 10 24
|
|
LC Display nope yup yup yup
|
|
Dialup Feature Access yup yup yup yup
|
|
Busy Lamp Field nope nope yup nope
|
|
With Headset nope yup yup yup
|
|
Weight 0.9kg 1.1kg 1.2kg 1.3kg
|
|
Dimensions(width mm) 180 229 260 280
|
|
Dimensions(length mm) 195 218 218 220
|
|
Dimensions(height mm) 99 99 99 99
|
|
|
|
|
|
Peripheral Equipment:-
|
|
^^^^^^^^^^^^^^^^^^^^
|
|
|
|
-Analogue Terminal Adaper
|
|
This enables analogue equipment such as fax machines, modems, and BS6317
|
|
phones to be connected to the systems as well as external extensions.
|
|
|
|
-Call Logging Interface
|
|
This optional add-on unit links to an external device - from a simple
|
|
serial printer to a sophisticated call management system.
|
|
|
|
-AC15 Interface
|
|
The AC15 interface gives Norstar systems the ability to support AC15A
|
|
4-wire private circuit. Compact systems can support two circuits,
|
|
Modular systems can support a maximum of 14.
|
|
|
|
|
|
Technical Specifications : Norstar Compact
|
|
^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Max Capacity : 6 exchange lines (MF or LD), 16 extensions
|
|
Switching : Fully digital, non-blocking
|
|
Control : Stored program on upgradable cassette
|
|
Private Circuit Cap. : 2
|
|
Recall : Timed break or earth
|
|
Power Requirements : 240V AC/50Hz
|
|
Power Consumption : 35W
|
|
Operating Temp. Range : 0(inf)-50(inf)C
|
|
Humidity Range : 5%-95%!?
|
|
Dimensions : Width Height Depth
|
|
CCU : 356mm 557mm 87mm
|
|
Box Connection : 356mm 274mm 87mm
|
|
Weight : CCU Box Connection
|
|
: 5.25kg 2.0 kg
|
|
|
|
Technical Specifications : Norstar Modular
|
|
^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Max Capacity : 128 ports:80 exchange lines, 24 extensions
|
|
8 exchange lines, 120 extensions
|
|
Switching : Fully digital, non-blocking
|
|
Control : Stored program on upgradable cassette
|
|
Private Circuit Cap. : 14
|
|
Recall : Timed break or earth
|
|
Power Requirements : 240V AC/50Hz
|
|
Power Consumption : 24W(basic system), 120W(fully loaded)
|
|
Operating Temp. Range : o(inf)-50WC
|
|
Humidity Range : 5%-95%!?and underwater??
|
|
Dimensions : Width Height Depth
|
|
CCU : 395mm 625mm 171mm
|
|
Box Connection : 210mm 790mm 95mm
|
|
Line Module : 198mm 625mm 171mm
|
|
Extension Module : 98mm 625mm 171mm
|
|
Weight: -
|
|
Central Control Unit : 9.0 kg
|
|
Box Connection : 3.9 kg
|
|
Line Module : 6.0 kg
|
|
Extension Module : 2.4 kg
|
|
|
|
|