1
0
mirror of https://github.com/bdring/Grbl_Esp32.git synced 2025-09-02 02:42:36 +02:00

Added addiitonal settings. Fixed Polar Coaster's buttons

Settings
 - Added stallguard
 - Added user machine settings
Polar Coaster
 - Fixed the invert mask for the buttons
This commit is contained in:
bdring
2019-12-04 20:15:56 -06:00
parent e9e6270467
commit b1b6c16256
6 changed files with 97 additions and 15 deletions

View File

@@ -21,6 +21,12 @@
"30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle."
"31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle."
"32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed."
"33","Spindle PWM Freq","16-bit","Spindle PWM Freq"
"34","Spindle PWM Off Value","16-bit","Spindle PWM Off Value"
"35","Spindle PWM Min Value","16-bit","Spindle PWM Min Value"
"36","Spindle PWM Max Value","16-bit","Spindle PWM Max Value"
"80-84","User integer Values","unsigned 16-bit","Reserved for custom machine use"
"90-94","User Floating point value","float","Reserved for custom machine use"
"100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter."
"101","Y-axis travel resolution","step/mm","Y-axis travel resolution in steps per millimeter."
"102","Z-axis travel resolution","step/mm","Z-axis travel resolution in steps per millimeter."
@@ -36,3 +42,5 @@
"140-145","Motor run current","Amps","Motor run current for SPI (Trinamic) type motors"
"150-155","Motor hold current","Percent","Hold current in percent of run current for SPI (Trinamic) type motors"
"160-165","Motor microstepping","micros/step","Number of microsteps per step for SPI (Trinamic) type motors"
"170-175","Motor Stallguard Value","0-255","Value of Stallguard setting for SPI (Trinamic) type motors"
1 $-Code Setting Units Setting Description
21 30 Maximum spindle speed RPM Maximum spindle speed. Sets PWM to 100% duty cycle.
22 31 Minimum spindle speed RPM Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle.
23 32 Laser-mode enable boolean Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed.
24 33 Spindle PWM Freq 16-bit Spindle PWM Freq
25 34 Spindle PWM Off Value 16-bit Spindle PWM Off Value
26 35 Spindle PWM Min Value 16-bit Spindle PWM Min Value
27 36 Spindle PWM Max Value 16-bit Spindle PWM Max Value
28 80-84 User integer Values unsigned 16-bit Reserved for custom machine use
29 90-94 User Floating point value float Reserved for custom machine use
30 100 X-axis travel resolution step/mm X-axis travel resolution in steps per millimeter.
31 101 Y-axis travel resolution step/mm Y-axis travel resolution in steps per millimeter.
32 102 Z-axis travel resolution step/mm Z-axis travel resolution in steps per millimeter.
42 140-145 Motor run current Amps Motor run current for SPI (Trinamic) type motors
43 150-155 Motor hold current Percent Hold current in percent of run current for SPI (Trinamic) type motors
44 160-165 Motor microstepping micros/step Number of microsteps per step for SPI (Trinamic) type motors
45 170-175 Motor Stallguard Value 0-255 Value of Stallguard setting for SPI (Trinamic) type motors
46