1
0
mirror of https://github.com/bdring/Grbl_Esp32.git synced 2025-08-16 19:44:07 +02:00

Update setting_codes_en_US.csv

This commit is contained in:
bdring
2020-04-04 10:16:01 -05:00
committed by GitHub
parent 95738dc305
commit ee05491c4e

View File

@@ -21,10 +21,10 @@
"30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle." "30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle."
"31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle." "31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle."
"32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed." "32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed."
"33","Spindle PWM Freq","16-bit","Spindle PWM Freq (reboot to take effect)" "33","Spindle PWM Freq","float (percent)","Spindle PWM Freq (reboot to take effect)"
"34","Spindle PWM Off Value","16-bit","Spindle PWM Off Value (reboot to take effect)" "34","Spindle PWM Off Value","float (percent)","Spindle PWM Off Value (reboot to take effect) Example 46.9 = 46.9%"
"35","Spindle PWM Min Value","16-bit","Spindle PWM Min Value (reboot to take effect)" "35","Spindle PWM Min Value","float (percent)","Spindle PWM Min Value (reboot to take effect)"
"36","Spindle PWM Max Value","16-bit","Spindle PWM Max Value (reboot to take effect)" "36","Spindle PWM Max Value","float (percent)","Spindle PWM Max Value (reboot to take effect)"
"80-84","User integer Values","unsigned 16-bit","Reserved for custom machine use" "80-84","User integer Values","unsigned 16-bit","Reserved for custom machine use"
"90-94","User Floating point value","float","Reserved for custom machine use" "90-94","User Floating point value","float","Reserved for custom machine use"
"100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter." "100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter."
1 $-Code Setting Units Setting Description
21 30 Maximum spindle speed RPM Maximum spindle speed. Sets PWM to 100% duty cycle.
22 31 Minimum spindle speed RPM Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle.
23 32 Laser-mode enable boolean Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed.
24 33 Spindle PWM Freq 16-bit float (percent) Spindle PWM Freq (reboot to take effect)
25 34 Spindle PWM Off Value 16-bit float (percent) Spindle PWM Off Value (reboot to take effect) Spindle PWM Off Value (reboot to take effect) Example 46.9 = 46.9%
26 35 Spindle PWM Min Value 16-bit float (percent) Spindle PWM Min Value (reboot to take effect)
27 36 Spindle PWM Max Value 16-bit float (percent) Spindle PWM Max Value (reboot to take effect)
28 80-84 User integer Values unsigned 16-bit Reserved for custom machine use
29 90-94 User Floating point value float Reserved for custom machine use
30 100 X-axis travel resolution step/mm X-axis travel resolution in steps per millimeter.