1
0
mirror of https://github.com/nophead/NopSCADlib.git synced 2025-08-06 23:46:30 +02:00

Now makes the build instruction TOC manually because GFM does not implement [TOC]

This commit is contained in:
Chris Palmer
2019-06-11 08:04:35 +01:00
parent bdbe6c1ed1
commit 8297dc75ba
2 changed files with 37 additions and 16 deletions

View File

@@ -1,3 +1,4 @@
<a name="TOP"/>
# MainsBreakOutBox
13A socket break out box with 4mm jacks to measure voltage and / or load current and earth leakage current.
@@ -17,11 +18,16 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
---
## Table of Contents
[TOC]
1. [Parts list](#Parts_list)
1. [Base Assembly](#base_assembly)
1. [Feet Assembly](#feet_assembly)
1. [Mains In Assembly](#mains_in_assembly)
1. [Main Assembly](#main_assembly)
[Top](#mainsbreakoutbox)
[Top](#TOP)
---
<a name="Parts_list"/>
## Parts list
| <span style="writing-mode: vertical-rl; text-orientation: mixed;">Base</span> | <span style="writing-mode: vertical-rl; text-orientation: mixed;">Feet</span> | <span style="writing-mode: vertical-rl; text-orientation: mixed;">Mains&nbsp;In</span> | <span style="writing-mode: vertical-rl; text-orientation: mixed;">Main</span> | <span style="writing-mode: vertical-rl; text-orientation: mixed;">TOTALS</span> | |
|--:|--:|--:|--:|--:|:--|
@@ -44,9 +50,11 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
| | | | | | **3D Printed parts** |
| &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;4&nbsp; | &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;4&nbsp; | &nbsp;&nbsp;&nbsp;foot.stl |
| &nbsp;&nbsp;1&nbsp; | &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;.&nbsp; | &nbsp;&nbsp;1&nbsp; | &nbsp;&nbsp;&nbsp;socket_box.stl |
[Top](#mainsbreakoutbox)
[Top](#TOP)
---
<a name="base_assembly"/>
## Base Assembly
### Vitamins
|Qty|Description|
@@ -70,9 +78,10 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
![base_assembled](assemblies/base_assembled_tn.png)
[Top](#mainsbreakoutbox)
[Top](#TOP)
---
<a name="feet_assembly"/>
## Feet Assembly
### Vitamins
|Qty|Description|
@@ -105,9 +114,10 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
![feet_assembled](assemblies/feet_assembled_tn.png)
[Top](#mainsbreakoutbox)
[Top](#TOP)
---
<a name="mains_in_assembly"/>
## Mains In Assembly
### Vitamins
|Qty|Description|
@@ -143,9 +153,10 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
![mains_in_assembled](assemblies/mains_in_assembled_tn.png)
[Top](#mainsbreakoutbox)
[Top](#TOP)
---
<a name="main_assembly"/>
## Main Assembly
### Vitamins
|Qty|Description|
@@ -185,4 +196,4 @@ Earth leakage can be measured Canadian CSA style by disconnected the neutral lin
![main_assembled](assemblies/main_assembled_tn.png)
[Top](#mainsbreakoutbox)
[Top](#TOP)